WATER & ENVIRONMENTAL

MERCURY ANALYZER

  • Simple to operate.
  • Rugged/Versatile design for laboratory and field.
  • Ultra-low detection limit and highest selectivity
  • Real-time operation mode for air and gases.
  • Direct determination of mercury in liquid and solid matrices within 60 seconds (attachments required). No sample preparation, no use of hazardous chemicals or bottled gases
  • Built-in performance verification test cell and auto zero function
  • Wide dynamic measuring range (four orders of magnitude)
  • Controlled by a keypad or a computer via USB interface
  • Data logger for 122 hours of data acquisition, averaging, and storage
  • Rechargeable battery for up to 12 hours’ operation
  • Sample weigh: 10-500 mg
  • Upper limit of the measurement ranges of concentration for a 20 mg sample: 200 mg/kg
  • Time for one measurement with air pumping rate: 1 l/m; 1-5 min
  • Size and weight of analyser: 470x210x110 mm, 7.5 kg
Product Brochure [PDF]
MERCURY ANALYZERS

AUTOCLAVES

AUTOCLAVES
  • Chamber Material Polished SUS304 medical stainless steel.
  • Max. Pressure 0.3MPa
  • Rated Working Pressure 0.22MPa
  • Max. Temperature 150°C
  • Working Temp. Range 105-134°C
  • Temp. Accuracy ±0.1°C
  • Timing Range 0~999 min
  • Dynamic Pulse Exhaust Time 0~9 times
  • Water Requirement Distilled water or demineralized water
  • Standard Accessories Stainless steel basket, 1pc
Product Brochure [PDF]

MICROBIAL AIR SAMPLER

  • Sampling head port flow rate: 0.38m/s, basically same with clean room wind speed (isokinetic sampling)
  • Automatic control sample volume: 10 ~ 6000L, minimum unit:10L
  • Parameter settings and sampling records storage: 99 sampling parameters
  • Setting record; 2000 sample data records.
  • Applicable Petri dish: Φ 70 ~ 90 × 15 mm
Product Brochure [PDF]
MICROBIAL AIR SAMPLERS

WATER PURIFICATION SYSTEM

WATER PURIFICATION SYSTEMS
  • Pure water outlet High pure, Ultra-pure water
  • Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing reminder
  • Water source required Ro water
  • DI water.5-45C,1atm
  • Post active carbon filter×+1Mixed bed resin cartridge×+1Ultra pure polishing resin cartridge× +4
  • 0.2μm terminal filter×1
  • +Double wavelength (254&185 nm)UV cartridge×5000+1 Do
Product Brochure [PDF]

MERCURY MONITORS

  • Direct continuous measurements
  • Low detection limit and wide range of measurement
  • Highest selectivity
  • No chemicals, no carrier, and zero gases
  • Stable calibration
  • Automatic zero drift and span drift correction
  • Automatic recalculation to standard conditions
  • Auto control and preventive maintenance functions
  • Robustness and low maintenance
  • Customized operation parameters and communication protocol
  • Air flow rate: 7–10 L/min
  • Air temperature: -20 to +40 °C
  • Number of sampling points: 2 – 16
  • Sampling line: up to 150 m
Product Brochure [PDF]
MERCURY MONITORS

BENZENE ANALYZER

BENZENE ANALYZER
  • Simple to operate, fully automated, self-validating analyzer
  • Real-time operation mode
  • Low detection limit and high selectivity
  • Built-in test cell and auto zero function
  • Wide dynamic measuring range
  • Controlled by a keypad or a computer via USB interface
  • Data logger for 122 hours of data acquisition, averaging, and storage
  • Rugged/Versatile design for indoor and field applications
  • Rechargeable battery for up to 12 hours of operation
  • Measurement range:0.1 – 500 mg/m3
  • Averaging interval: 1 s – 5 min
  • Zero drift correction: Automatic
  • Air flow rate: 7–10 lpm
Product Brochure [PDF]

BOD ANALYZER

  • Measurement range:0-4000mg/L
  • Measurement Accuracy:≤±10%
  • Number of tests:1-6
  • Data Storage: 10000sets testing data
  • Recording interval:5-180mins
  • Test days:1-30days
  • 7 inch LED touch display
  • Operation mode: touch screen man-machine interactive operation
  • Printing method:Thermal line printing
Product Brochure [PDF]
BOD ANALYZER

COD HEATING BLOCK

COD HEATING BLOCK
  • Determination of COD, TOC, total phosphate and total nitrogen
  • Temperature range up to 200 deg C
  • Timer up to 999 minutes
  • Accuracy: ±0.2°C (at 150°C)
  • Dimensions: W 189 x H 116 x D 315 mm
  • 4 Digital LED of set temperature, set time, process temperature, residual time display
Product Brochure [PDF]

DENSITY METERS

  • Measuring method Natural Oscillation type
  • Measurement object Liquid sample test materials
  • Temperature compensation Up to 10 entries for temperature compensation coefficient and converted temperature
  • Automatic calibration All density values of pure water needed for auto calibration can be stored.
  • Number of data: 1,100 samples
  • External output
Product Brochure [PDF]
DENSITY METERS

DISSOLVED-OXYGEN METERS

DISSOLVED-OXYGEN METERS
  • Parameters: Concentration/Saturation/℃
  • Range: DO: 0.00~45.00mg/L
  • DO Saturation: 0.0~300.0%
  • Temperature: -5.0~115.0℃
  • Accuracy: DO: ±0.10 mg/L
  • DO Saturation: ±2.0%FS
  • Temperature: ±0.2℃
  • Stability: (±0.07mg/L)/1h
  • Response Time: ≤45s(90% respond at 20℃)
  • Zero Error: ≤0.10mg/L
  • Barometric Pressure Calibration: (77.0~110.0) KPa
  • Temp Compensation: Automatic: 0.0~40.0℃
Product Brochure [PDF]

FREE CHLORINE & TOTAL CHLORINE METERS

  • free chlorine, total chlorine measurement
  • Range: 0 to 3.5mg/L
  • Auto range
  • Measuring principal: photo meter method
  • Light source: LED, 525nm
  • Record Max Min Value
  • 10PCs free & total powder DPD are included
  • Free & total 1.0mg/L standard solution
Product Brochure [PDF]
FREE CHLORINE & TOTAL CHLORINE METER

MANIFOLDS

MANIFOLDS
  • Body: Anodized aluminium
  • Control valve:Plated copper
  • Handle: Anodized aluminium
  • Hose barb: Plated copper
  • Number of branch: 3
  • Filter diameter: Optional
  • Funnel capacity: Optional
Product Brochure [PDF]

UV-VIS SPECTROPHOTOMETERS

  • Function: Absorbance, Transmittance or Concentration measurements
  • Spectral Bandwidth 4nm Wavelength Accuracy ±2nm
  • Wavelength Repeatability 0.8nm
  • Output USB Port & Parallel Port printer
  • WAVELENGTH RANGE (NM)-200-1000.
  • TYPE: UV/VIS, vis
Product Brochure [PDF]
UVV SPECTROPHOTOMETERS

PTFE DRY PUMPS

PTFE DRY PUMPS
  • Free Air Displacement, Comes standard with 115V line cord and convenient power switch
  • The economic Model 2019 diaphragm vacuum pump is durable and chemical resistant
  • Use Model 2019 for vacuum filtration, desiccation, degassing, and other mid-range vacuum applications
Product Brochure [PDF]

LABORATORY VACUUM PUMPS

  • 13l/min,266mbar,90-260V 50/60Hz +AC/DC adapter, Schuko, UK and US plug leads + 12VDC
  • Powerful, portable, economical
  • Advanced chemical resistance
  • Suggested Applications: Vacuum Filtration
  • Bring vacuum to where you need it. GEMINI pumps operate on DC power and are readily used with a car adapter or AC adapter. Excellent vacuum for filtration or sampling - 190 torr(266 mbar), 13 l/min. Small, lightweight, portable, includes gauge and vacuum regulator. Polyacrylamide heads, fluoropolymer elastomer diaphragms, tubing, valves
Product Brochure [PDF]
LABORATORY VACUUM PUMP

LEADPAINTCHECK STARTUP KIT PHOTOMETER 476 NM

LEADPAINTCHECK STARTUP KIT PHOTOMETER 476 NM
  • Direct read parameters: Lead in Paint, Lead in Water, Lead in Soil, Mercury in Water, and Cadmium in Water.
  • Easy-to-use eXact® Strip/Photometer reagent
  • 0.01 ppm (mg/L) precision with no visual color matching required
  • Waterproof meter (IP-67) and it floats
  • Automatic test timer & 120 test memory (saves last 20 tests per menu)
  • Auto calibrated meter
Product Brochure [PDF]

COLORIMETER 2 WAVELENGTHS FOR WATER INSPECTIONS 525NM & 638NM

  • Colorimeter 525 & 638 nm
  • For water testing by "dry chemistry" method
  • Alkalinity 0-200ppm
  • Aluminium 0-0.9 ppm
  • Ammonia 0-2.3 ppm
  • Chlorine -free/total/as NaCl
  • Copper 0-11 ppm
  • Fluoride 0-1.5 ppm
  • Total hardness 0-300 ppm
Product Brochure [PDF]
COLORIMETER 2 WAVELENGTHS FOR WATER INSPECTIONS 525NM & 638NM

EXACT CHLORINE - PLUS - KIT 525 NM

EXACT CHLORINE - PLUS - KIT 525 NM
  • Measurable parameters: Free& total Chlorine 0-11 ppm
  • Bromine 0-14 ppm
  • Ozone 0.01-9 ppm
  • Chlorine dioxide 0-12 ppm
  • Peracetic acid 0-9 ppm
  • Hydrogen Peroxide 0-3 ppm
  • Transmissions 99.9-0.01%T
  • High range Chlorine 0-300 ppm
Product Brochure [PDF]

EXACT MICRO 7 KIT 525 NM

  • Photometer 525nm tester for chlorine, hardness, pH, alkalinity etc.
  • Measurement range: (ppm)
  • Free/total Chlorine: 0-11
  • High range Cl free:0-300
  • Bromine: 0-14
  • Alkalinity: 5-300
  • Copper: 0.04-8
  • Hardness: 1-320
  • Total Iron: 0.03-5
  • Ozone: 0-11
  • 20-teast memory for each menu (160 total)
  • Sample volume: 4 ml
Product Brochure [PDF]
EXACT MICRO 7 KIT 525 NM

SPECTROPHOTOMETER UV-VIS FOR WATER ANALYSIS

SPECTROPHOTOMETER VISIBLE & UV-VISIBLE
  • Optimal accuracy with the reference beam: more accurate, less drift, and no need to make a blank measurement every time you start an analysis
  • Acquisition system: 2 times faster than previous technologies
  • Better ergonomy with a large color screen
  • Special mode: the measurements can be done according to the customizable mathematical formulation, integration of additional variables and measurement conditions
  • Improvement of the lamp lifetime: up to 4 years on Uviline 9300 and no need to change the lamp for Uviline 9600
  • Guaranteed stray light < 1%
Product Brochure [PDF]

AIR QUALITY METERS

  • CO2, CO, O2, Humidity, Dew point, Temp. 6 in 1
  • CO2 range: 0 to 4,000 ppm x 1 ppm.
  • O2 range: 0 to 30.0 % x 0.1 %.
  • CO range: 0 to 1,000 ppm x 1 ppm
  • Humidity range: 10 to 95 %RH.
  • Dew point Temp. and Wet Bulb Temp. measurement.
  • Sampling Time: 2 secs to 8 hours 59 min. 59 sec
Product Brochure [PDF]
AIR QUALITY METERS

Academia, Research & Pathology

read more

Water & Environmental

read more

Food & Beverage

read more

Medical & Diagnostic

read more

Petrochemical & Mining

read more

Pharmaceutical

read more

Get in touch

For full detailed information about our products, please contact us